Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Urol Open Sci ; 63: 89-95, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38585592

RESUMO

Background and objective: Data regarding open conversion (OC) during minimally invasive surgery (MIS) for renal tumors are reported from big databases, without precise description of the reason and management of OC. The objective of this study was to describe the rate, reasons, and perioperative outcomes of OC in a cohort of patients who underwent MIS for renal tumor initially. The secondary objective was to find the factors associated with OC. Methods: Between 2008 and 2022, of the 8566 patients included in the UroCCR project prospective database (NCT03293563), who underwent laparoscopic or robot-assisted minimally invasive partial (MIPN) or radical (MIRN) nephrectomy, 163 experienced OC. Each center was contacted to enlighten the context of OC: "emergency OC" implied an immediate life-threatening situation not reasonably manageable with MIS, otherwise "elective OC". To evaluate the predictive factors of OC, a 2:1 paired cohort on the UroCCR database was used. Key findings and limitations: The incidence rate of OC was 1.9% for all cases of MIS, 2.9% for MIRN, and 1.4% for MIPN. OC procedures were mostly elective (82.2%). The main reason for OC was a failure to progress due to anatomical difficulties (42.9%). Five patients (3.1%) died within 90 d after surgery. Increased body mass index (BMI; odds ratio [OR]: 1.05, 95% confidence interval [CI]: 1.01-1.09, p = 0.009) and cT stage (OR: 2.22, 95% CI: 1.24-4.25, p = 0.008) were independent predictive factors of OC. Conclusions and clinical implications: In MIS for renal tumors, OC was a rare event (1.9%), caused by various situations, leading to impaired perioperative outcomes. Emergency OC occurred once every 300 procedures. Increased BMI and cT stage were independent predictive factors of OC. Patient summary: The incidence rate of open conversion (OC) in minimally invasive surgery for renal tumors is low. Only 20% of OC procedures occur in case of emergency, and others are caused by various situations. Increased body mass index and cT stage were independent predictive factors of OC.

2.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613608

RESUMO

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers
4.
J Endourol ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38429915

RESUMO

Urothelial carcinoma (UC) affecting the urinary tract is recognized as one of the prevalent types of cancer, ranking fifth in terms of incidence. However, it is important to note that upper tract urothelial carcinoma (UTUC), in comparison to bladder cancer, is relatively uncommon and represents a minority of UC cases, accounting for ∼5% to 10%. It is worth emphasizing that as much as 60% of UTUC cases are invasive at the time of diagnosis, in contrast to 25% of bladder cancer cases. These statistics highlight the urgent need for well-designed, multidisciplinary strategies to guide optimal management for this vulnerable patient population, aiming to control treatment variability and minimize the risks associated with undertreatment and overtreatment. Methods: In this study, we present a comparative analysis of the contemporary guidelines on UTUC management from the European Association of Urology (EAU) and the American Urological Association/Society of Urologic Oncology (AUA/SUO) released in 2023. Our objective is to contrast the different guidelines and examine the evidence on which their recommendations are based. Results: By thoroughly reviewing the guidelines from both organizations, we observed substantial agreement on the management of UTUC. However, we also identified noticeable differences among these guidelines, leading to a wide range of recommendations. These disparities might stem from variations in clinical practices, regional preferences, and the availability of resources. It is crucial to acknowledge that both the EAU and AUA/SUO base their guidelines on the latest scientific evidence and expert consensus within their respective regions. Conclusions: These findings underscore the importance of ongoing collaboration, knowledge exchange, and harmonization of guidelines to improve the standard of care for UTUC globally. Future research should focus on identifying areas of consensus and bridging the gaps between different international guidelines to enhance the management outcomes for this challenging disease.

5.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
6.
Fr J Urol ; 34(4): 102609, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38460936

RESUMO

Angiosarcoma is a rare malignancy derived from endothelial cells, which behaves aggressively. Primary angiosarcoma of the kidney is even rarer, and its clinical and radiological presentations do not differ from clear cells renal cell carcinoma (ccRCC). Management protocols are not standardized, although nephrectomy is usually performed. Subsequent treatments (chemotherapy, radiotherapy, and lately, targeted therapies) vary considerably. Herein, we report the case of a middle-aged patient harboring primary angiosarcoma of the left kidney and discuss its presentation and management in light of current guidelines. The case is described for its rarity and masquerading nature.

10.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280001

RESUMO

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Nefrolitíase , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio , Cistina , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio
11.
Eur Urol Focus ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37940392

RESUMO

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

12.
World J Urol ; 41(12): 3437-3447, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37932561

RESUMO

PURPOSE: To provide a technological description of the new pulsed solid-state Thulium:YAG laser (Tm:YAG). In addition, current available literature on Tm:YAG lithotripsy is also reviewed. MATERIALS AND METHODS: Medline, Scopus, Embase, and Web of Science databases were used to search for Tm:YAG operating mode articles. RESULTS: Tm:YAG technology works with a laser cavity with thulium-doped YAG crystal, pumped by laser diodes. Laser beam operates at 2013 nm, with an adjustable peak power (≥ 1000 W) and the minimal fiber laser diameter is of 200 µm. It has an intermediate water absorption coefficient and peak power-pulse duration. Various pulse modulations are proposed, aiming to minimize stone retropulsion. Multiple comparative in vitro studies suggest that Tm:YAG's ability to fragment stones is similar to the one of the Ho:YAG laser; on the contrary, its ability to dust all stone types is similar to the one of the TFL, with a low retropulsion. A single in vivo study assessed Tm:YAG lithotripsy feasibility. CONCLUSIONS: The new pulsed solid-state thulium:YAG laser could represent a safe and effective compromise between Ho:YAG laser and TFL for endoscopic lithotripsy, either in retrograde intra-renal surgeries or in percutaneous nephrolithotomy.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Hólmio
15.
J Clin Med ; 12(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37834918

RESUMO

BACKGROUND: An accurate estimation of the stone burden is the key factor for predicting retrograde intra-renal surgical outcomes. Volumetric calculations better stratify stone burden than linear measurements. We developed a free software to assess the stone volume and estimate the lithotrity duration according to 3D-segmented stone volumes, namely the Kidney Stone Calculator (KSC). The present study aimed to validate the KSC's reproducibility in clinical cases evaluating its inter-observer and intra-observer correlations. METHODS: Fifty patients that harbored renal stones were retrospectively selected from a prospective cohort. For each patient, three urologists with different experience levels in stone management made five measurements of the stone volume on non-contrast-enhanced computed tomography (NCCT) images using the KSC. RESULTS: the overall inter-observer correlation (Kendall's concordance coefficient) was 0.99 (p < 0.0001). All three paired analyses of the inter-observer reproducibility were superior to 0.8. The intra-observer variation coefficients varied from 4% to 6%, and Kendall's intra-observer concordance coefficient was found to be superior to 0.98 (p < 0.0001) for each participant. Subgroup analyses showed that the segmentation of complex stones seems to be less reproductible. CONCLUSIONS: The Kidney Stone Calculator is a reliable tool for the stone burden estimation. Its extension for calculating the lithotrity duration is of major interest and could help the practitioner in surgical planning.

16.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831156

RESUMO

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitíase , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Cálculos Urinários/terapia , Oxalato de Cálcio , Hólmio
17.
World J Urol ; 41(12): 3765-3771, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37833547

RESUMO

BACKGROUND AND OBJECTIVE: We aimed to evaluate the concordance between the pre-settings ranges of thulium fibre laser (TFL) (Coloplast TFL Drive, Denmark) with easy-to-use graphical user interface and the laser settings used by a high-volume endo-urologist during surgical procedures. MATERIALS AND METHODS: In October 2022, we prospectively collected data of 67 patients who underwent TFL Drive (Coloplast, Denmark) for the management of urinary stones. Urothelial tumour (upper tract urinary cancer (UTUC) and bladder) 200 and 150 µm laser fibres were used for procedures. Stones characteristics (size and density) tumours and stenosis localizations, laser-on time (LOT), and laser settings were recorded. We also assessed the ablation speed (mm3/s), laser power (W), and Joules/mm3 values for each lithotripsy. RESULTS: A total 67 patients took part in the study. Median age was 52 (15-81) years. 55 (82%), 8 (12%), and 4 (6%) patients presented urinary stones, urothelial tumour, and stenosis, respectively. Median stone volume was 438 (36-6027) mm3 and median density was 988 (376-2000) HU. Median pulse energy was 0.6 (0.3-1.2), 0.8 (0.5-1) and 1 J for urinary stones, urothelial tumour and stenosis respectably. Endoscopically stone-free rate was 89%. Graphical user interface and surgeon accordance with the safety range were observed in 93.2%, 100% and 100% for urinary stones, UTUC and stenosis, respectively. CONCLUSION: During endoscopic procedures for urinary stones treatment, it is frequently needed to change laser parameters. These new TFL and GUI technology parameters remained in the pre-set security range in 94.1% of procedures.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Neoplasias , Cálculos Urinários , Humanos , Pessoa de Meia-Idade , Túlio , Litotripsia a Laser/métodos , Constrição Patológica , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico
18.
World J Urol ; 41(11): 3345-3353, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37728745

RESUMO

PURPOSE: Flexible ureteroscopy (fURS) is steadily gaining popularity in the management of renal calculi, including those located in the lower pole (LP). Due to difficulty in accessing to the LP of kidney in minority of cases with fURS and reports of lower stone-free rate (SFR), it is still considered as a challenge in selected cases. The purpose of the review was to analyze the various aspects of fURS for LP stones. METHODS: An extensive review of the recent literature was done including different factors such as anatomy, preoperative stenting, stone size, flexible scopes, types of lasers, laser fibers, suction, relocation, stone-free rates, and complications. RESULTS: The significance of various lower pole anatomical measurements remain a subject of debate and requires standardization. Recent improvements in fURS such as single-use digital scopes with better vision and flexibility, high power laser, thulium fiber laser, smaller laser fiber, and accessories have significantly contributed to make flexible ureteroscopy  more effective and safer in the management of LP stone. The utilization of thulium fiber lasers in conjunction with various suction devices is being recognized and can significantly improve SFR. CONCLUSIONS: With the significant advancement of various aspects of fURS, this treatment modality has shown remarkable efficacy and gaining widespread acceptance in management of LP kidney stones. These developments have made the fURS of LP stones less challenging.


Assuntos
Cálculos Renais , Ureteroscopia , Humanos , Túlio , Ureteroscópios , Cálculos Renais/cirurgia , Rim , Resultado do Tratamento
19.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37587366

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Poeira , Litotripsia a Laser/métodos , Cálculos Urinários/terapia
20.
J Clin Med ; 12(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37568309

RESUMO

INTRODUCTION: Thulium lasers (TLs), namely the Thulium fiber laser (TFL) and the Thulium:YAG (Tm:YAG), are being increasingly adopted for the conservative treatment of upper urinary tract urothelial carcinoma (UTUC). However, to date, the real clinical impact of TLs on UTUC management remains not well-characterized. We performed a review of the literature to summarize the current evidence on TLs for UTUC treatment. MATERIALS AND METHODS: We performed a systematic review in January 2023 using the Embase and Medline online databases, according to the PRISMA recommendations and using the PICO criteria. Outcomes of interest were: (i) to assess the safety and feasibility of TLs in the treatment of UTUC, and (ii) to evaluate the oncological outcomes in terms of tumor recurrence and conservative treatment failure. Moreover, we described TL characteristics and its interaction with soft tissue. RESULTS: a total of 458 articles were screened, and six full texts including 273 patients were identified. All the included studies were retrospective series. Mean patient age ranged from 66 to 73 years. The indication of a conservative treatment was elective and imperative in 21.7-85% and 15-76% of cases, respectively. Laser power settings varied from 5 to 50 W. No intraoperative complications were reported, and all the procedures were successfully performed. The tumor recurrence rate was 17.7-44%, and the indication to radical nephroureterectomy was 3.7-44% during a follow-up of 6-50 months. Most of the postoperative complications were mild and transient, and ureteral strictures were reported in two studies. Major limitations were the retrospective nature of the studies, the small sample sizes, and the short follow-up. CONCLUSIONS: TL is an effective and safe technology for endoscopic UTUC treatment. However, current available literature lacks prospective and multicentric studies with large population sizes and long-term follow-up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...